Magnesium anode for Calmar Beredar'n 100-120L. Mounted in the top with a 32mm socket
Product description
Supervision and Maintenance
Protective anode (magnesium anode}
The water heater is equipped with a protective anode as standard. Its task is to sacrifice itself if pores have formed in the corrosion protection (enamel). The anode must be replaced when necessary, and at the latest after 24 months.
If the anode is not replaced, the heater's warranty is void.
Contact your plumber for replacement.
Safety valve
The valve combination located at the cold and hot water connection has a safety valve fitted. This should be exercised a few times a year by turning its black knob until water comes out
into the waste pipe (note: be careful, as it is hot)
Mixing valve
The task of the mixing valve is to mix the water in the heater with incoming cold water so that the desired temperature reaches the tap. Adjustable between 35-65° C. We recommend setting it to approx. 55° C
Draining the heater
- Start by disconnecting the power by pulling out the heater's wall plug. Turn off the incoming cold water on the valve pipe.
- Open a hot water tap in the house.
- Turn the black knob (hold it in the open position) until it stops dripping from the waste pipe.
- Keep the hot water tap open while the heater is being drained.
Cleaning
If the heater's outer casing needs cleaning, use ordinary dish/window detergent and a cloth. Strongly corrosive agents must not be used.
Resetting the overheat protection
If for any reason the heater becomes overheated, the overheat protection will trip. This can be reset by loosening the red knob on the bottom left of the heater and pressing the button in. If the fault reoccurs, contact your installer.
Specifications
Weight 500g